Home
About LMI
LMI Awards
Contact Us
Request Information Form
Product Training Form
Applications
LMI Automotive Applications
LMI Aerospace Applications
LMI Glass Applications
Products
LMI Products
LMI 200 Series Probe
LMI 241 Series Gage
LMI 241 BWV2 Series Gage
LMI 585 Plus Digital Transmitter
LMI 440 Data Collector
LMI TruPosition Series Probes
LMI Autogage Systems
LMI Seal Gap Systems
LaserGauge Systems
LMI RippleGauge
LMI Software
Quality
LMI Quality
Customer Statisfaction Form
Warranty Information
Instructions
LMI Mastering Instructions
LMI 200 Series Probe Mastering
LMI 241 Series Gage Mastering
LMI 241 BWV2 Series Gage Mastering
LMI Seal Gap Series Gage Mastering
LMI TruPosition Series Probe Mastering
LMI 440 Series Data Collector Mastering
LMI 585 Plus Data Transmitter Mastering
LMI 300 Series Gage Mastering
LMI 770 Series Gage Mastering
On-Line Support
LMI Support
LMI Tech Support
LMI Customer Service
LMI Knowledge Base
Distributors
Distributor Information Request Form
LMI Request Information Form
LMI Product Training Form
Members
Login

                    LMI AutoGage Software


 

AutoGage Setup Screen

This portion of the program is where the user enters probe location and specification limits. The default setting are user customizable with tolerances and offsets for each individual part. The Autogage system can handle various characteristics and each characteristic point can be assigned  to a 32 port multiplex.

The Null Indicator uses two opposing probes to determine whether a part is centered To enable the Null Indicator feature check the “Null Indicator” option. The following additional options are

displayed.

 

The Null indicator has user defined customizable tolerances for each custom part. Defines keyboard point parameters. Keyboard Data Points are readings that are typed in using the keyboard. The Keyboard points have user defined customizable tolerances for each custom part.

 

AutoGage Graphics Screen

The Graphic section is a user customized location where graphic files can be added to the part file. 

 

Supported graphics include: AI, BMP – Windows Bitmap, CDR, CGM, CTM, CH3, DIB, DRW, DXF -AutoCAD, EPS, GEM, GIF,HGL, JPG, MET, NAP, PCD, PCX, PDI, PIC,PIC, PCT, RND, SYM, SYS3, TGA, TIF, WMF – Windows Metafile,

and WPG.

The characteristics boxes can be manually placed around the graphic to associate the proper characteristic with the part location. The font can also be resized to match smaller or larger graphics.

The options of showing individual point characteristic with there tolerance can be either turned on or turned off.

 

AutoGage Calibration Screen

A calibration point is High Cal, Low Cal, or Master on a single probe or on all probes. Probes can becalibrated individually or all at the same time using the All Probes option. 

All probes would be calibrated at the same time for systems where all the probes can be in the 
correct  position at the same time (i.e. spring extend probes in the extended position, retracted position for spring retract).

 All systems will have at least one calibration point that can be calibrated using the All Probes option (the natural position of the probe such as extended for spring extend).

   

Systems with air extend or retract will have at least two calibration points that can be calibrated using the All Probes option (High Cal and Low Cal). Systems that use a perfect part, prototype, or

negative mold to calibrate the Master use the All Probes option for this calibration point.

 

Runtime Screen

There are three different display types to choose from in the runtime. The values screen, the graphics screen, and the bar graph screen.

 

Samples can be taken while viewing the Values, Bar Graph, or Graphic display screens. Use the remote pendant switch to sample data. (Samples can also be taken by pressing ALT+S on the PC keyboard.)

The message below will flash briefly to indicate that a sampling has occurred.

Data will be taken for each point on the displayed component. The data will be colorfully displayed to indicate whether the reading is within specification limits (green), within control limits (yellow) or out of specification limits (red). The screen will automatically scroll to the next checking type in the selected part file. If other check types. The data will be exported to all of the export files, after the completion

of the sampled part.

AutoGage Documentation

 AutoGage Software Manual

 AutoGage System Brochure

 

LMI Software Requirements

 LMI AutoGage Software

 

Related Software Links

 UGI Software

 Seal Gap Software

 Data Collect Software